Spinal catheter revision in pediatric intrathecal baclofen pumps: risk factors and postoperative outcomes

Amanda M Mosher1, Emma Hartman1, Dylan Keusch1

  • 11Department of Neurosurgery and.

Neurosurgical Focus
|June 1, 2024
PubMed

Insights

Younger age and increased spasticity in cerebral palsy patients increase the risk of intrathecal baclofen (ITB) pump catheter malfunction. This can lead to higher infection rates and ITB system removal, necessitating further study of catheter patency.

Area of Science:

  • Neurology
  • Pediatric Surgery
  • Biomedical Engineering

Background:

  • Intrathecal baclofen (ITB) pumps are crucial for managing spasticity in pediatric cerebral palsy (CP).
  • Spinal catheter malfunction is a significant complication, but its risk factors and consequences are not fully understood.

Purpose of the Study:

  • To identify risk factors for spinal catheter malfunction in ITB pumps.
  • To characterize the clinical outcomes following ITB pump revision or replacement.

Main Methods:

  • Retrospective review of pediatric patients undergoing ITB pump procedures (2010-2023).
  • Comparison of patients requiring spinal catheter revision (SCRC) versus those with abdominal pump replacement only (APRC).
  • Multivariable regression analysis to determine factors associated with catheter revision and outcomes.

Main Results:

  • Younger age and higher preoperative lower-extremity tone (Modified Ashworth Scale) were linked to spinal catheter revision.
  • Spinal catheter revision was associated with increased postoperative infection rates (17.1% vs 0%) and higher rates of subsequent ITB system removal (24.4% vs 7.4%).
  • Postoperative ITB doses were lower in the SCRC group, and 31.7% of revisions were unanticipated.

Conclusions:

  • Younger age and increased spasticity are potential risk factors for ITB spinal catheter obstruction.
  • Catheter obstruction leads to increased infection risk, ITB system removal, and potentially suboptimal tone management.
  • Routine assessment of catheter patency may be warranted to prevent complications from insidious catheter malfunction.
Abstract