Related Experiment Video
Updated: Jun 24, 2025

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
An alternative silicone-based passive sampling device to derive organotin concentrations in the aqueous phase
Alan Carlos de Almeida1, Rodrigo Moço Batista1, Gilberto Fillmann1
1Programa de Pós-Graduação em Química Tecnológica e Ambiental (PPGQTA), Escola de Química e Alimentos (EQA), Universidade Federal do Rio Grande - FURG, 96203-900, Rio Grande, RS, Brazil; Instituto de Oceanografia, Universidade Federal do Rio Grande (IO-FURG), Av. Itália s/n, Campus Carreiros, 96203-900, Rio Grande, RS, Brazil.
Abstract:
Organotin compounds (OTs) are well studied in various environmental compartments, with a critical focus on the water column as their primary entry point into aquatic ecosystems. In this context, a method for the analysis of organotin (OTs) in water using silicone rubber-based passive sampling was optimized, validated, and field-tested. Validation covered crucial parameters, including the limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, linearity, and matrix effect. The method was shown to be robust (R2 ≥ 0.99), with recoveries between 70.2 and 114.6%, and precise (CV < 12.8%) (N = 3). LODCw and LOQCw were ≤15 and ≤ 48 pg Sn L-1, respectively, for TBT and TPhT. The matrix effect showed to be low (>-20% ME < 20%) for all OTs but TPhT (69.4%). The silicone rubber-water partition coefficients (Log Ksr,w) were estimated at 3.37 for MBT, 3.77 for DBT, 4.17 for TBT, 3.49 for MPhT, 3.83 for DPhT, and 4.22 for TPhT. During the field study carried out between October 2021 and February 2022 at the entrance of the Port of Santos navigation channel (Southeastern Brazil), sampling rates ranged between 4.1 and 4.6 L d-1, and the equilibrium was achieved for MBT, DBT, MPhT, and DPhT after ∼45 days of deployment. The freely dissolved concentrations varied between 134 and 165 pg Sn L-1 for TBT, 388 and 610 pg Sn L-1 for DBT, and 1114 and 1509 pg Sn L-1 for MBT, while MPhT, DPhT, and TPhT were below the limit of detection. Results pointed out that J-FLEX® rubber-based passive sampling is a suitable and reliable alternative method for the continuous monitoring of OTs in the water column.
More Related Videos
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016
11:43Dissolved Solute Sampling Across an Oxic-Anoxic Soil-Water Interface Using Microdialysis Profilers
Published on: March 24, 2023