Related Experiment Video
Updated: Jun 24, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Comparison of high-flow nasal cannula and conventional nasal cannula during deep sedation for endoscopic submucosal
Seungwon Lee1, Ji Won Choi2, In Sun Chung1
1Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-Ro, Gangnam-Gu, Seoul, 06351, Korea.
Purpose:
Adequate oxygenation and airway management during deep sedation can be challenging. We investigated the effect of high-flow nasal cannula (group HF) and conventional nasal cannula (group CO) during sedation for endoscopic submucosal dissection (ESD).
Methods:
Patients undergoing ESD with deep sedation were enrolled. The primary outcome was difference in lowest oxygen saturation (SpO2) between the groups. Incidence of hypoxia (SpO2 < 90%), patients with SpO2 < 95%, hypercapnia, and airway interventions; operator satisfaction; and adverse events were recorded.
Results:
Thirty-two patients in each group completed the study. The mean of minimum SpO2 values was significantly higher in group HF than in group CO (96.8% ± 4.2% vs. 93.3% ± 5.3%, p = 0.005). The incidence of hypoxia was comparable between the groups (4 [12.5%] vs. 6 [18.8%], p = 0.491); however, patients with SpO2 < 95% were significantly less in group HF (5 [15.6%] vs. 18 [56.3%], p = 0.003). Incidence of hypercapnia was higher in group HF than in group CO (14 [46.7%] vs. 5 [16.7%], p = 0.013). Airway rescue interventions were significantly less common in group HF. Satisfaction of operators and post-procedural complications were comparable between the two groups. In multivariable analysis, group CO and higher body mass index were risk factors for airway managements (odds ratio [95% confidence interval]: 6.204 [1.784-21.575], p = 0.004; 1.337 [1.043-1.715], p = 0.022, respectively).
Conclusions:
Compared to conventional nasal cannula, high-flow nasal cannula maintained higher minimum SpO2 value during deep sedation with propofol-remifentanil for ESD.
Trial Registration:
Clinical Trial Registry of the Republic of Korea (KCT0006618, https://cris.nih.go.kr ; registered September 29, 2021; principal investigator: Ji Won Choi).
More Related Videos
03:58Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Suctioning the Nasopharyngeal Airway
Equipment Required
Stages of General Anesthesia
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...