High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain
Published on: May 10, 2012
Sustained bias of spatial attention in a 3 T MRI scanner
Stefan Smaczny1, Leonie Behle1,2, Sara Kuppe1
1Center of Neurology, Division of Neuropsychology, Hertie-Institute for Clinical Brain Research, University of Tübingen, Hoppe Seyler Str. 3, 72076, Tübingen, Germany.
Abstract:
When lying inside a MRI scanner and even in the absence of any motion, the static magnetic field of MRI scanners induces a magneto-hydrodynamic stimulation of subjects' vestibular organ (MVS). MVS thereby not only causes a horizontal vestibular nystagmus but also induces a horizontal bias in spatial attention. In this study, we aimed to determine the time course of MVS-induced biases in both VOR and spatial attention inside a 3 T MRI-scanner as well as their respective aftereffects after participants left the scanner. Eye movements and overt spatial attention in a visual search task were assessed in healthy volunteers before, during, and after a one-hour MVS period. All participants exhibited a VOR inside the scanner, which declined over time but never vanished completely. Importantly, there was also an MVS-induced horizontal bias in spatial attention and exploration, which persisted throughout the entire hour within the scanner. Upon exiting the scanner, we observed aftereffects in the opposite direction manifested in both the VOR and in spatial attention, which were statistically no longer detectable after 7 min. Sustained MVS effects on spatial attention have important implications for the design and interpretation of fMRI-studies and for the development of therapeutic interventions counteracting spatial neglect.
More Related Videos
08:45Mapping Cortical Dynamics Using Simultaneous MEG/EEG and Anatomically-constrained Minimum-norm Estimates: an Auditory Attention Example
Published on: October 24, 2012
13:00Measuring Attention and Visual Processing Speed by Model-based Analysis of Temporal-order Judgments
Published on: January 23, 2017
Related Concept Videos
Atomic Nuclei: Larmor Precession Frequency
Atomic Nuclei: Magnetic Resonance
Atomic Nuclei: Nuclear Relaxation Processes
NMR Spectrometers: Resolution and Error Correction
Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...