Related Experiment Video
Updated: Aug 16, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Mammographic density assessment: comparison of radiologists, automated volumetric measurement, and artificial
Hye Joung Eom1, Joo Hee Cha1, Woo Jung Choi1
1Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Background:
Artificial intelligence-based computer-assisted diagnosis (AI-CAD) is increasingly used for mammographic exams, and its role in mammographic density assessment should be evaluated.
Purpose:
To assess the inter-modality agreement between radiologists, automated volumetric density measurement program (Volpara), and AI-CAD system in breast density categorization using the Breast Imaging-Reporting and Data System (BI-RADS) density categories.
Material And Methods:
A retrospective review was conducted on 1015 screening digital mammograms that were performed in Asian female patients (mean age = 56 years ± 10 years) in our health examination center between December 2022 and January 2023. Four radiologists with two different levels of experience (expert and general radiologists) performed density assessments. Agreement between the radiologists, Volpara, and AI-CAD (Lunit INSIGHT MMG) was evaluated using weighted kappa statistics and matched rates.
Results:
Inter-reader agreement between expert and general radiologists was substantial (k = 0.65) with a matched rate of 72.8%. The agreement was substantial between expert or general radiologists and Volpara (k = 0.64-0.67) with a matched rate of 72.0% but moderate between expert or general radiologists and AI-CAD (k = 0.45-0.58) with matched rates of 56.7%-67.0%. The agreement between Volpara and AI-CAD was moderate (k = 0.53) with a matched rate of 60.8%.
Conclusion:
The agreement in breast density categorization between radiologists and automated volumetric density measurement program (Volpara) was higher than the agreement between radiologists and AI-CAD (Lunit INSIGHT MMG).
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography

