Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Lung ultrasound for prediction of surfactant requirement in Indian preterm neonates: a diagnostic accuracy study
Deeksha Gupta1, Mayank Priyadarshi2, Suman Chaurasia1
1Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India.
Abstract:
Surfactant replacement for respiratory distress syndrome (RDS) is currently guided by oxygen (FiO2) requirement in preterm neonates. Lung ultrasound (LUS) has emerged as an important predictive tool; however, there is a paucity of evidence from developing countries. The objective of this study was to determine the diagnostic accuracy of the LUS score in comparison to standard criteria based on FiO2 requirement for prediction of surfactant requirement. In this prospective study, preterm neonates of < 34 weeks' gestation with RDS were included within 2 h of life. Surfactant was administered if the FiO2 requirement exceeded 30%. Baseline characteristics, respiratory parameters, and LUS clips were recorded soon after birth and compared between the surfactant and non-surfactant groups. LUS scoring was later performed by masked assessors which was not used in the management of neonates. Among 82 neonates (mean gestation 30.6 weeks and weight 1375 g) included in the study, 33 (40.2%) received surfactant. The surfactant group had a higher Silverman score, required higher FiO2 and mean airway pressure, and needed invasive ventilation more frequently. The mean (± SD) LUS score was significantly higher in the surfactant (9.4 ± 3.2) compared to the non-surfactant group (5.1 ± 2.1). The diagnostic accuracy of LUS scoring was determined by ROC curve analysis (AUC (95% CI): 0.83 (0.74-0.92), p < 0.01). A cutoff score of ≥ 8 for LUS was considered optimal for the prediction of surfactant requirement (sensitivity and specificity (95% CI) of 70% (51-84) and 80% (66-90), respectively). Conclusion: Lung ultrasound is a valid diagnostic tool for the prediction of surfactant requirements in resource-limited settings. What is Known: • Lung ultrasound has a good diagnostic accuracy in predicting the need for surfactant administration in preterm neonates in developed countries, but its role in developing countries is unclear. What is New: • Lung ultrasound proved to be a valid diagnostic tool in predicting surfactant replacement therapy in resource-limited settings. • The diagnostic performance of lung ultrasound was better in neonates on non-invasive ventilation, compared to invasive ventilation.
More Related Videos
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
08:21Point-of-Care Ultrasound: A Review of Ultrasound Parameters for Predicting Difficult Airways
Published on: April 7, 2023