Modeling the Intelligibility Benefit of Active Noise Cancelation in Hearing Devices That Improve Signal-to-Noise

Andrew T Sabin1, Dale McElhone1, Daniel Gauger1

  • 1Research, Bose Corporation, Framingham, MA, USA.

Trends in Hearing
|June 4, 2024
PubMed

Related Concept Videos

Sound Waves: Interference00:53

Sound Waves: Interference

Sound waves can be modeled either as longitudinal waves, wherein the molecules of the medium oscillate around an equilibrium position, or as pressure waves. When two identical waves from the same source superimpose on each other, the combination of two crests or two troughs results in amplitude reinforcement known as constructive interference. If two identical waves, that are initially in phase, become out of phase because of different path lengths, the combination of crests with troughs...
3.7K
Design Example01:23

Design Example

The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
324
Characteristics of Practical Op Amps01:16

Characteristics of Practical Op Amps

A difference amplifier, a crucial component in numerous electronic devices, ideally amplifies only the difference-mode signal, which is the difference between two input signals. However, in practical circuits, the output voltage depends on both the differential gain and the common-mode gain.
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
513
Active Filters01:25

Active Filters

Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
818
Instrumentation Amplifier01:25

Instrumentation Amplifier

An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
500