Related Experiment Video
Updated: Jun 24, 2025

Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
A 1.11 mm2 IVUS SoC With -Range Plane Wave Transmit Beamforming at 40 MHz
Abstract:
Intravascular ultrasound (IVUS) imaging catheters are significant tools for cardiovascular interventions, and their use can be expanded by realizing IVUS imaging guidewires and microcatheters. The miniaturization of these devices creates challenges in SNR due to the need for higher frequencies to provide adequate resolution. An integrated IVUS system with transmit beamforming can mitigate these limitations. This work presents the first practical highly integrated system-on-a-chip (SoC) with plane wave transmit beamforming at 40 MHz for IVUS on guidewire or microcatheters. The front-end circuitry has a 20-channel ultrasound transmitter (Tx) and receiver (Rx) array interfaced with a capacitive micromachined ultrasound transducer (CMUT) array. During each firing, all 20 Tx are excited with the same analog delay with respect to each other, which can be continuously adjusted between 0 and 10 ns in two directions, generating a steerable plane wave in a range of +/-50 for a phased array at 40 MHz. The unit delays are generated via a voltage-controlled delay line (VCDL), which only needs two external controls, one tuning the unit delay and the other determining the steering direction. The SoC is fabricated using a 180-nm high-voltage (HV) CMOS process and features a slender active area of 0.3 mm 3.7 mm. The proposed SoC consumes 31.3 mW during the receiving mode. The beamformer's functionality and the SoC's overall performance were validated through acoustic characterization and imaging experiments.
More Related Videos
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Related Concept Videos
Plane Electromagnetic Waves I
The EM field is assumed...
Standing Electromagnetic Waves
Suppose a sheet of a perfect conductor is placed in the yz-plane, and a linearly polarized electromagnetic wave traveling in the...
Propagation Speed of Electromagnetic Waves
Transmission Line Design Considerations
Electromagnetic Waves
IR Frequency Region: X–H Stretching