Jove
Visualize
Contact Us

Related Concept Videos

Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

382
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
382
Chromatographic Resolution01:15

Chromatographic Resolution

463
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
463
Column Efficiency: Rate Theory01:12

Column Efficiency: Rate Theory

310
The rate theory of chromatography provides quantitative insight into the shapes and widths of elution bands. These bands are based on the random-walk mechanism governing molecular migration within a column. The Gaussian profile of chromatographic bands arises from the cumulative effect of random molecular motions as they progress through the column.
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
310
Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

2.1K
Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
2.1K
Principles Of Column Chromatography01:13

Principles Of Column Chromatography

6.8K
The chromatography technique was first invented in 1901 by Michael S. Tswett, a Russian botanist, to separate plant pigments using organic solvents. Further, in 1941, Archer John Porter Martin and R. L. M. Synge modified the technique by packing silica gel into a column. A mixture of amino acids was then separated on the packed column using chloroform and water mixture as the mobile phase. This was the first report on column chromatography. At present, column chromatography is a widely used...
6.8K
Chromatography: Introduction01:10

Chromatography: Introduction

4.3K
Chromatography is a technique used to separate compounds based on differences of partitioning between two phases, the stationary phase and the mobile phase.
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
4.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Chemical space blind spots: how chromatographic selectivity dictates chemical measurability and coverage of LC-HRMS comprehensive analysis.

Chemical communications (Cambridge, England)·2026
Same author

From Spectra to Local Networks: Evaluating MS<sup>2</sup> Similarity Metrics.

Analytical chemistry·2026
Same author

Advancing the Discovery of Emerging Contaminants: A Leap in Technology and Data.

Environmental science & technology·2026
Same author

Communicating Confidence in the Reliability of Micro- and Nanoplastic Identification in Human Health Studies.

Environment & health (Washington, D.C.)·2026
Same author

Determination of Copolymer Block-Length Distributions Using Fragmentation Data Obtained from Tandem Mass Spectrometry.

Macromolecules·2026
Same author

Measurable Feature Prediction for Estimating Chemical Space Coverage in LC-ESI-HRMS Nontargeted Analysis.

Analytical chemistry·2026
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 24, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.0K

Generating realistic data through modeling and parametric probability for the numerical evaluation of data processing

Nino B L Milani1, Alan Rodrigo García-Cicourel2, Jan Blomberg2

  • 1Van't Hoff Institute for Molecular Science (HIMS), University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands.

Analytica Chimica Acta
|June 4, 2024
PubMed
Summary

A new platform models and reconstructs 2D chromatography data, enabling objective evaluation of data processing algorithms. This advances analytical method development for complex separation technologies.

Keywords:
Data synthesisPeak detectionPeak modelingTwo-dimensional chromatography

More Related Videos

Curtain Flow Column: Optimization of Efficiency and Sensitivity
06:44

Curtain Flow Column: Optimization of Efficiency and Sensitivity

Published on: June 12, 2016

6.5K
Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
08:56

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry

Published on: November 22, 2024

609

Related Experiment Videos

Last Updated: Jun 24, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.0K
Curtain Flow Column: Optimization of Efficiency and Sensitivity
06:44

Curtain Flow Column: Optimization of Efficiency and Sensitivity

Published on: June 12, 2016

6.5K
Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
08:56

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry

Published on: November 22, 2024

609

Area of Science:

  • Analytical Chemistry
  • Chromatography

Background:

  • Comprehensive two-dimensional chromatography (2D-LC) generates complex data.
  • Objective evaluation of data processing algorithms is hindered by a lack of standardized data.

Purpose of the Study:

  • To develop a versatile platform for modeling and reconstructing 2D chromatography data.
  • To enable objective performance assessment of baseline correction and noise removal algorithms.

Main Methods:

  • A Skewed Lorentz-Normal model was used to represent individual peaks.
  • Probability distributions were created for parameter sampling to balance real and synthetic data.
  • The platform was applied to both 2D gas chromatography (2D-GC) and 2D liquid chromatography (2D-LC) data.

Main Results:

  • A dataset with 458 peaks was generated for 2D-GC data, achieving a Root Mean Square Error (RMSE) of 0.0048 or lower.
  • Minimal residuals were observed when comparing reconstructed data to original experimental data.
  • The platform demonstrated successful application to both 2D-GC and 2D-LC datasets.

Conclusions:

  • The developed platform facilitates quantitative assessment of algorithm performance through probability distributions.
  • This innovation opens new avenues for developing faster, more accurate, and simpler data analysis strategies.
  • Objective data evaluation is crucial for advancing complex separation technologies in analytical chemistry.