Related Experiment Video
Updated: Jun 24, 2025

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Inside-Out Anchor Placement: A Technique to Instrument Far Medial Anchors in Acetabular Labral Repair
Fabien Meta1, Zachary C Reuter1, Xuankang Pan1
1Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, U.S.A.
Abstract:
Labral tears most commonly occur anteriorly between the 12- and 3-o'clock positions, with the 12-o'clock position denoted as superior and the 3-o'clock position denoted as anterior. When approaching the 3-o'clock position and beyond, suture anchor placement becomes difficult given the challenging arthroscopic trajectory and an overall thin anterior rim of cortical bone for anchor purchase, resulting in a narrow angle of safe drilling. The purpose of this technical note is to present a safe and reproducible method of suture anchor placement during acetabular labral repair approaching the 3- and 4-o'clock positions, with the 12-o'clock position representing the superior anatomic location and the 3-o'clock position representing the anterior anatomic location regardless of hip laterality. We use an inside-out anchor placement technique to place far medial anchors, which differs from the conventional techniques (e.g., outside-in technique) in which anchor placement is performed along the external margin of the acetabular labrum.