Fatina I Fadel1, Doaa M Salah1, Mohamed A Abdel Mawla2
1Pediatric department, Faculty of Medicine, Cairo University, 4 Extension of Nobar Street, Cairo, Egypt.
Background:
Accurate volume status assessment and dry weight achievement are the most challenging goals for a nephrologist. We aimed to evaluate the role of ultrasonographic parameters including lung ultrasound and inferior vena cava (IVC) measurements as practical methods of volume status assessment in children on hemodialysis by comparing them with established techniques, such as clinical evaluation and bioimpedance spectroscopy.
Methods:
A prospective cross-sectional study compared pre- and post-dialysis volume status using bioimpedance spectroscopy (BIS) parameters and clinical data with ultrasonographic lung B-lines and IVC parameters in children on regular hemodialysis.
Results:
A total 60 children (mean age 9.4 ± 2.8 years) were enrolled. Twenty patients (33.3%) were clinically overloaded to varying degrees (17 patients had mild to moderate signs of fluid overload and 3 patients had moderate to severe signs of fluid overload). All other patients (66.7%) were clinically euvolemic. Sonographic parameters were significantly lower post-dialysis than pre-dialysis, including lung B-line count and IVC diameter. IVC collapsibility index mean was significantly higher post-dialysis than pre-dialysis. There was a significant correlation between the lung B-line count, IVC parameters, and BIS-measured overhydration both before and after hemodialysis. Nine patients had ≥ 8 B-lines post-dialysis, only three of them were hypertensive.
Conclusions:
Clinical criteria alone are not specific for determining accurate fluid status in pediatric hemodialysis patients. Lung B-line score, IVC parameters, and BIS may be complementary to each other and to clinical data. Lung B-lines outperform IVC measurements and BIS in subclinical volume overload detection in pediatric hemodialysis patients.
Related Concept Videos
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...