Background:
The need of a neurostimulator for a successful nerve block was questioned in different block types after ultrasound had become standard.
Aim:
To determine the effect of neurostimulator use on block success in the costoclavicular block (CCB).
Methods:
Sixty patients undergoing upper limb surgery were enrolled in the study. Patients using ultrasound and injection pressure manometer were divided as Group USP, and those using ultrasound, injection pressure manometer, and neurostimulator were divided as Group USPN. After block was applied, sensory and motor block levels were measured on a numeric scale. The block was considered successful when the desired score was reached or general anesthesia was not required intraoperatively. The number of successful and unsuccessful blocks for each group was summed up. The successful block rate was compared as the primary objective. Block application time, time to readiness for surgery, the number of needle passes, diaphragm paralysis rate, and complication rate were compared as secondary goals.
Results:
Block success rate was 90% (27/30) in Group USP and 96.7% (29/30) in Group USPN. There was no statistical difference in terms of block success rate. Block application time was significantly shorter in Group USP (207.2 ± 32.7 s) when compared to Group USPN (280.9 ± 70.1 s). Other secondary outcomes were similar.
Conclusion:
Neurostimulator use did not affect block success in the CCB. Neurostimulator utilization prolonged block application time explicitly and did not change the complication rate. Ultrasound and injection pressure manometer are sufficient for a safe and successful CCB.
More Related Videos
06:48Ethanol-Induced Cervical Sympathetic Ganglion Block Applications for Promoting Canine Inferior Alveolar Nerve Regeneration Using an Artificial Nerve
Published on: November 30, 2018
06:36Nerve Stimulator-guided Injection of Autologous Stem Cells Near the Equine Left Recurrent Laryngeal Nerve
Published on: September 26, 2018
Related Concept Videos
Depolarizing Blockers: Pharmocokinetics
Depolarizing Blockers: Mechanism of Action
Succinylcholine is the most commonly used depolarizing blocker. Chemically, it constitutes two molecules of acetylcholine joined together by an acetate methyl group. They act on the receptors in the same way as acetylcholine. Because...
Nondepolarizing (Competitive) Neuromuscular Blockers: Pharmacological Actions
Although all competitive neuromuscular blockers are designed...
Neuromuscular Junction And Blockade
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...