Related Experiment Video
Updated: Jun 24, 2025

Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
Published on: December 12, 2013
Estimation on the hourly near-surface temperature lapse rate and its time-varying characteristics
Caiya Yue1,2, Liya Hu1, Yueguan Yan3
1School of Geography and Environment, Liaocheng University, Liaocheng, 252059, China.
Abstract:
Since much of the current researches have focused on daily, monthly or annual near-surface (2 m) temperature lapse rate (NSTLR), there is little guidance on best estimation practices and analyses of time-varying characteristics for the hourly NSTLR. To estimate hourly NSTLR and identify its time-varying characteristics accurately and objectively, this study proposed a robust estimation strategy based on IGGIII equivalent weight using multiple linear regression models. The accuracy and reliability of the proposed method was verified. The results show that the robust estimation strategy can further improve the hourly NSTLR solution accuracy relative to the least square (LSQ) method, especially in the time period of relatively high temperature. The hourly NSTLR was positively correlated with temperature, with a 24-h average maximum of 0.604 °C/100 m at universal time coordinated (UTC) 7.2 h and minimum of 0.284 °C/100 m at UTC 20.5 h, respectively. Throughout the year, the NSTLR was the largest from June to August, with an average median of around 0.492 °C/100 m. However, from November to the following January, the NSTLR value was the smallest, with a mean median of about 0.323 °C/100 m. In addition, the hourly NSTLR values were essentially less than the constant value of 0.65 °C/100 m. When the hourly NSTLR estimated based on the proposed method was applied to the temperature interpolation, the interpolation accuracies at the highest altitude (1545 m) and other meteorological stations (below 310 m) can increase by 22.4 % and 8.1 %, respectively, relative to the hourly NSTLR calculated by the LSQ method, and increased by 55.6 % and 13.0 %, respectively, relative to the no-NSTLR correction. The results are important for the fine establishment of high spatiotemporal resolution temperature fields and for the study of climatic phenomena characterized with rapid spatiotemporal variation.
More Related Videos
10:29Experimental Methodology for Estimation of Local Heat Fluxes and Burning Rates in Steady Laminar Boundary Layer Diffusion Flames
Published on: June 1, 2016
08:41A Rapid Laser Probing Method Facilitates the Non-invasive and Contact-free Determination of Leaf Thermal Properties
Published on: January 7, 2017
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Boundary Layer Characteristics
Temperature Dependent Deformation
Absorption of Radiation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Random Error