Related Experiment Video
Updated: May 6, 2026

A New Murine Model of Endovascular Aortic Aneurysm Repair
Published on: July 7, 2013
Flow alteration surgery using a radial artery graft for recurrent ruptured vertebral artery dissecting aneurysm after
Masaru Abiko1, Yukishige Hashimoto1, Masakazu Mitsunobu1
1Department of Neurosurgery, JA Onomichi General Hospital, Onomichi, Japan.
Background:
Ruptured vertebral artery dissecting aneurysm (VADA) is often treated surgically with coil embolization and sometimes recurs. We herein report a case of recurrent ruptured VADA after stent-assisted coil embolization (SAC) that was successfully treated with flow alteration surgery using a radial artery (RA) graft.
Case Description:
A 67-year-old woman presented with headache and coma. Enhanced CT revealed subarachnoid hemorrhage due to right VADA. Since the left VA was hypoplastic, the aneurysm was treated with SAC. However, follow-up angiography revealed recurrence of the aneurysm. Additional embolization was not considered due to the small size of the recurrent lesion and the presence of a stent; therefore, flow alteration surgery was performed using a RA graft. There were no neurological deficits after surgery or recurrence.
Conclusion:
Flow alteration surgery using a RA graft is useful for recurrent VADA after SAC.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management