Omnipolar conduction velocity mapping for ventricular substrate characterization: Impact of CV estimation method and
Johanna B Tonko1, Mahmoud Ehnesh2, Edmon Vigmond3
1Institute for Cardiovascular Science, University College London, London, United Kingdom.
Background:
Areas of abnormal or heterogeneous conduction velocity (CV) are important ablation targets for ventricular tachycardias, yet precise assessment of CV in clinical contact mapping remains challenging. Numerous different CV estimation methods have been proposed.
Objective:
This study aimed to compare the automated local activation time (LAT)-independent omnipolar-based CV estimation method termed wave speed (WS) with 4 established LAT-based methods to formally establish the quantitative differences between them.
Methods:
High-density contact maps in patients with structurally normal hearts during sinus rhythm (SR) and ventricular ectopy (VE) were retrospectively analyzed. CV was assessed and compared by 5 methods: omnipolar WS, gradient method, planar wavefront fitting, circular wavefront fitting, and radial basis function. CV variations based on electrogram (EGM) type (unipolar, bipolar, and omnipolar), catheter movement, and surrogate markers for catheter contact were analyzed.
Results:
The study included 23 patients (47.8% male; 45.7 ± 17.3 years) with 22 SR maps (11 left ventricle, 11 right ventricle) and 16 VE maps (9 left ventricle, 7 right ventricle). The WS algorithm yielded statistically significant higher CV estimates in SR (mean, 1.41 ± 0.18 m/s) and VE (mean, 1.23 ± 0.18 m/s) maps compared with all LAT-based estimation methods, with absolute differences ranging from 0.1 m/s to 0.81 m/s. Median pointwise differences in SR and VE between WS and LAT-based methods were high, ranging from 0.55 ± 0.15 m/s (WS vs planar wavefront fitting) to 0.67 ± 0.16 m/s (WS vs radial basis function). For LAT-based methods, use of unipolar EGMs yielded significantly higher CV estimates than bipolar or omnipolar EGMs in SR.
Conclusion:
The CV estimation method has an important, statistically significant impact on ventricular CV measurements. Future work will focus on how these differences affect identification of pathologic conduction slowing in scar-related substrate.
More Related Videos
09:35Preclinical Cardiac Electrophysiology Assessment by Dual Voltage and Calcium Optical Mapping of Human Organotypic Cardiac Slices
Published on: June 16, 2020
09:36Dual-Dye Optical Mapping of Hearts from RyR2R2474S Knock-In Mice of Catecholaminergic Polymorphic Ventricular Tachycardia
Published on: December 22, 2023
Related Concept Videos
Propagation Speed of Electromagnetic Waves
Electromagnetic Waves in Matter
Consider the electromagnetic wave passing through a dielectric medium. In such a case, Maxwell's equations get modified. In Ampere's law, ε0 , the dielectric permittivity of free space is replaced with ε, the permittivity of dielectric. Also, the vacuum permeability μ0 is replaced by the permeability of the medium, μ.
Furthermore, the...
Deriving the Speed of Sound in a Liquid
The speed of sound in fluids can be derived by considering a mechanical wave propagating...