Objective:
Osteoarthritis (OA) is a source of significant limitations for individuals, health systems, and economies. The most common complications of OA are often associated with risk factors related to chronic diseases, cardiovascular disease, and depression. In this article, a new kind of staple is proposed, designed to provide better strength when subjected to bending and torque loads.
Methods:
This innovative staple has been numerically tested and compared to a MEMOFIX staple by Smith + Nephew, in order to evaluate its mechanical behavior. The radius and ulna were fixed at the lower extremity, while the distal interphalangeal of the little finger was loaded with a bending load of 50 N and a torque moment of 500 N/mm2.
Results:
For the bending load, a maximum value of stress of 120 MPa in the traditional staple, while 90 MPa are registered in the innovative one. The torsional load produces a value of 107 MPa in the traditional staple and 85 MPa in the innovative one.
Conclusion:
Computational simulations showed the biomechanical performance of a new type of nitinol staple compared with a traditional one. This staple is designed with an elliptical shape in order to support different kinds of loads. Our results confirm an optimal mechanical behavior, compared to the traditional staple, in terms of the evaluated Equivalent Von Mises stress; also the contact force exerted by the innovative staple was increased.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
06:53Author Spotlight: Rapid Prototyping and Testing of Self-Expanding Nitinol Frames for Transcatheter Implantable Devices
Published on: March 7, 2025
Related Concept Videos
Equivalent Couples
Two couples are considered to be equivalent if they produce the same rotational effect on a rigid body. In other words, the two couples have the same magnitude and act in the same direction, causing the same angular displacement or acceleration in the body.
For instance, consider two couples lying in the plane of the page, with one having a pair of equal...
Method of Joints: Problem Solving I
Method of Joints: Problem Solving II
Machines
A free-body diagram of the...
Machines: Problem Solving II
Bearings: Problem Solving