Related Experiment Video
Updated: Jun 24, 2025

Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Clear amniotic fluid aspiration syndrome: A novel description of an old entity
Pierre-Yves Robillard1,2, Francesco Bonsante1,2, Brahim Boumahni1
1Service de Néonatologie, Centre Hospitalier Universitaire Sud Réunion, Saint-Pierre Cedex, La Réunion.
Background:
Clear amniotic fluid aspiration syndrome (CAF-AS) is a very rare event occurring in 0.25% of our term clear amniotic fluids deliveries. The study's aims were: 1. to characterize the risk factors and outcomes associated with Clear Amniotic Fluid Aspiration Syndrome and 2. to compare the outcomes of Clear Amniotic Fluid Aspiration to Meconium Aspiration.
Methods:
This was an observational study over a 22-year period in a single level-3 medical center. Compared were parturient/labor characteristics and neonatal outcomes in cases with suspected Clear Amniotic Fluid Aspiration to cases suspected for Meconium Aspiration.
Results:
Out of 79,620 term deliveries there were 66,705 (83.8%) clear amniotic fluids and 12,915 (16.2%) meconium stained amniotic fluid (MSAF). Of neonates born with clear amniotic fluid, 166 (0.25%) were diagnosed with Clear Amniotic Fluid Aspiration Syndrome (CAF-AS), while 202 (15.7%) of those born with MSAF, were diagnosed with aspiration syndrome (MSAF-AS). Both conditions had comparable rates of mild manifestation (67.5% vs 69.2%, p = 0.63). Persistent pulmonary hypertension (PPH) occurred 5 times less in CAF-AS than MSAF-AS (4% vs 20%, OR 0.17, P< 0.0001) Both conditions presented similar rates of surfactant without PPH (11.1% vs 13.4%, p = 0.87). There was 1 postnatal death in CAF-AS vs 10 in MSAF.
Conclusion:
CAF-AS were quantitatively quite similar in terms of need of actual active intervention of the neonatologists in the delivery room (166 vs 202, i.e. in terms of numbers of cases and not prevalence) to MSAF-AS.We identified in these cases two major specific causes: hyperkinetic explosive deliveries in multiparas and long-lasting episodes of maternal hypotension due to epidural/spinal anaesthesia during labor. Out of 140 million births per year in the world, it should be of concern that 3 million cases are neglected nowadays. Future studies should evaluate if this CAF-AS should benefit from a more active intervention such as immediate endotracheal suction at birth, this clear fluid being very easy to suction.
More Related Videos
07:36Modeling Encephalopathy of Prematurity Using Prenatal Hypoxia-ischemia with Intra-amniotic Lipopolysaccharide in Rats
Published on: November 20, 2015
08:50A Murine Model of Fetal Exposure to Maternal Inflammation to Study the Effects of Acute Chorioamnionitis on Newborn Intestinal Development
Published on: June 24, 2020
Related Concept Videos
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pleural Effusion I: Introduction
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's...
Pneumonia II: Pathophysiology
Suctioning the Nasopharyngeal Airway
Equipment Required
Acute Respiratory Failure-IV
Pleural Effusion II: Symptoms and Management
A pleural effusion is the abnormal collection of fluid between the parietal and visceral pleura layers of tissue that form the lining of the lungs and chest cavity. It can occur independently or due to surrounding parenchymal diseases, such as infection, malignancy, or inflammatory conditions.
Clinical Manifestations: