Optimizing Energy Delivery in Cardioversion: A Randomized PROTOCOLENERGYTrial of 2 Different Algorithms in Patients
Miklik Roman1, Rucki Lucjan1, Jiravsky Otakar2
1Department of Cardiology, Nemocnice Agel Trinec-Podlesi, Trinec, Czechia.
Background:
The optimal energy protocol for direct current cardioversion of atrial fibrillation remains uncertain. The Rational vs Maximum Fixed Energy (PROTOCOLENERGY) randomized trial compared a stepwise escalating energy algorithm (RaA, 150 J, 360 J, and 360 J) with a maximum fixed energy algorithm (MfA, 3 x 360 J).
Methods:
In a 1:1 randomized trial, 300 patients with atrial fibrillation received biphasic discharges via hand-held paddles in the anterolateral position. Primary endpoints were sinus rhythm at 1 minute and neurologic complications at 2 hours; secondary endpoints included sinus rhythm at 2 hours, skin changes and chest discomfort at 24 hours.
Results:
Sinus rhythm at 1 minute was achieved in 92.7% of RaA and 94.0% of MfA patients (P = 0.643) and maintained at 2 hours in 91.3% of both groups. There were no neurologic complications. The protocols differed significantly after the first shock (72.7% in RaA vs 83.3% in MfA; P = 0.026) but equalized after subsequent maximum energy shocks. Fewer RaA patients experienced skin redness compared with MfA patients (19.3% vs 36.0%, P = 0.001), which was attributed to the lower initial 150-J shock and total energy delivered (r = 0.243, P < 0.0001). Chest discomfort at 24 hours was not different between groups (P = 0.378). In multivariate analysis, lower body mass index (P < 0.001, cutoff 29 to 34 kg/m2) was associated with cardioversion success after the initial 150-J shock.
Conclusions:
Both protocols showed similar high cumulative efficacy, but RaA with the initial 150-J shock proved to be beneficial in patients with body mass index less than 29 to 34 kg/m2 because of fewer skin complications.
Clinical Trial Registration No:
NCT05148923.
More Related Videos
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Antiarrhythmic Drugs: Class II Agents as β-Adrenergic Blockers
Antiarrhythmic Drugs: Class III Agents as Potassium Channel Blockers
Antiarrhythmic Drugs: Class IV Agents as Calcium Channel Blockers
Verapamil, a calcium channel blocker, inhibits calcium movement across myocardial cell membranes and vascular smooth muscle. This results in the dilation of coronary and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...