[Study on the application value of portable pulse oximeter in adult patients with obstructive sleep apnea]
Abstract:
Objective: To evaluate the application value of portable pulse oximeter in adult obstructive sleep apnea (OSA). Methods: This study prospectively enrolled adult patients who underwent polysomnography (PSG) due to snoring at the Respiratory and Sleep Medicine Department of Peking University People's Hospital from July 2022 to July 2023. During PSG monitoring, CS-WOxi was continuously used to monitor blood oxygen levels. The consistency between 3% oxygen desaturation index (ODI3) measured by portable pulse oximeter and ODI3 of polysomnography was evaluated using difference test, Pearson's correlation coefficient, and Bland-altman method. Receiver operating characteristic curve was used to determine the optimal threshold for diagnosing OSA. Results: A total of 184 subjects were included, including 121 males (65.8%) and 63 females (34.2%). The mean age was 46.0 (34.3, 59.0) years, body mass index was 26.0 (23.3, 29.6) kg/m², and the apnea-hypopnea index was 18.2 (5.8, 40.8) events/h. There was a significant difference between CS-ODI3 and PSG-ODI3 [17.1(6.2, 42.7) vs. 14.0(2.9, 32.6), P<0.001], and the Pearson correlation coefficient was 0.93 (P<0.001). There was a good correlation between CS-ODI3 and PSG-AHI (r=0.92, P<0.001). Bland-Altman consistency test showed that the average difference between the two was 0.7 events/h, and the 95% consistency limit was (-17.9, 19.3 events/h). When the CS-ODI3≥5 events/h was used to identify OSA, the sensitivity was 94.4%, the specificity was 80.0%, and the accuracy was 91.3%. When PSG-AHI≥5 events/h was used as the diagnostic criteria, the area under the receiver operating characteristic curve was 0.933. Conclusion: Portable pulse oximeter can monitor pulse oxygen saturation accurately and has good sensitivity and specificity for OSA high-risk patients, and is a reliable tool for OSA screening.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Sleep Apnea
The condition is more prevalent among...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Special considerations while measuring pulse