Related Experiment Video
Updated: Jun 24, 2025

Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Published on: May 2, 2025
The efficient application of instilling negative pressure wound therapy with a hypochlorous acid-preserved wound
Marc R Matthews1, Luis G Fernández2, Michel He Hermans3
1Department of Surgery, Division of Trauma, Surgical Critical Care, Burns and Acute Care Surgery, Banner University of Arizona/University Medical Center, Tucson, AZ.
Background:
The use of negative pressure wound therapy with instillation and dwell time (NPWTi-d) has been shown to be effective in removing nonviable tissue, reducing bioburden, and promoting granulation tissue formation in acute and chronic infected wounds.
Objective:
To illustrate the clinical efficacy of the use of pure hypochlorous acid (pHA) antimicrobially preserved wound cleansing solution as the instillation fluid for NPWTi-d (NPWTi-d/pHA) in wound bed preparation in patients with complex wounds.
Case Report:
The treatment protocol for use of NPWTi-d/pHA in preparing wound beds for final closure is demonstrated in 3 illustrative cases of patients with complex wounds resulting from necrotizing infection and trauma with heavy contamination. All 3 patients developed a healthy-appearing wound bed deemed suitable for primary closure an average of approximately 1 month following initial surgical debridement.
Conclusion:
The cases presented demonstrate the ability of a pHA antimicrobially preserved wound cleansing solution used as the instillation fluid with NPWTi-d to aid in bacterial reduction, mechanical debridement, and promotion of wound healing. Use of NPWTi-d/pHA in these cases of extensive necrotizing infection and posttraumatic injury with heavy contamination allowed for final closure an average of 1 month after initial surgical debridement.
Related Concept Videos
Hand hygiene
Hand washing...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Suctioning the Nasopharyngeal Airway
Equipment Required