Related Experiment Video
Updated: Jun 24, 2025

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Conducted Electrical Weapon Fire Risk in the Presence of Supplemental Oxygen
Background:
Conducted electrical weapons (CEWs) are nonlethal weapons used in tactical environments. Tactical EMS (TEMS) operators provide patient care in environments where CEWs are present. CEWs may produce a spark that can be a source of ignition. When supplemental oxygen is in use by a TEMS operator, the flammability risk from the CEW is unknown.
Methods:
We measured oxygen levels over 20 minutes in an enclosed space with a supplemental oxygen source maximally flowing. Measurements were taken at various distances from the oxygen source to establish baseline concentrations. These concentrations were replicated within a plexiglass box where a CEW was activated to create a sparking arc between probes embedded in a fresh swine shoulder (with skin intact). Various flammable materials, typically found in a patient care setting were used as potential fuel sources.
Results:
The highest oxygen levels were achieved directly at the source. At 15cm from the source, the maximum oxygen concentration was 31.5%. Within the box, ignition was only achieved at oxygen concentrations greater than 45% and only when human hair was present as fuel. No ignition was achieved at oxygen levels below this regardless of the tested fuel present.
Conclusion:
Ignition from a CEW is possible at supplemental oxygen levels greater than 45% when human hair is present. In an enclosed space, oxygen concentration levels of 45% are only present within 15cm of a flush rate oxygen source. The likelihood of CEW-caused ignition in such settings with supplemental oxygen in use is extremely low.
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Atomic Emission Spectroscopy: Interference
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...