Related Experiment Video
Updated: Apr 9, 2026

Preparation and Use of Photocatalytically Active Segmented Ag|ZnO and Coaxial TiO2-Ag Nanowires Made by Templated Electrodeposition
Published on: May 2, 2014
Sandwich-structured continuous ZIF-8/Ti3C2 MXene/ZIF-8 for efficient sterilization: Enhanced photocatalytic activity,
Furong Xiong1, Huilin Hu2, Xiang Xue2
1College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou 310014, China.
Abstract:
The development of effective water purification systems is crucial for controlling and remediating environmental pollution, especially in terms of sterilization. Herein, we demonstrate elaborately designed composite nanosheets with a sandwich structure, composed of two-dimensional (2D) Ti3C2 MXene nanosheet core and conformal ZIF-8 ultrathin outer layers, and their potential applications in photocatalytic sterilization. The study results indicate that the conformal ZIF-8-MXene nanosheet exhibits an expanded light absorption range (826 nm), improved photothermal conversion efficiency (6.2 °C s-1), and photocurrent response, thus boosting photocatalytic sterilization efficiency (6.63 log10 CFU mL-1) against Escherichia coli under simulated sunlight within 90 min. Interestingly, 2D ZIF-8 layers exhibit positive zeta potential (19 mV), good hydrophilicity (40.6°), and local photogenerated-hole accumulation, possessing efficient bacteria-trapping efficiency. Membrane filters fabricated from optimized composite nanosheets exhibit an outstanding bacteria-trapping and sterilization efficiency (almost 100 %) against Escherichia coli under simulated sunlight within 30 min of the flow photocatalytic experiments. This work not only presents a rational structural design of the conformal and ultrathin anchoring of ZIF-8 onto a 2D conductive material for bacteria-trapping and sterilization, but also opens new opportunities for using metal-organic frameworks in photocatalytic disinfection of drinking water.
More Related Videos
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...

