Related Experiment Video
Updated: Jun 24, 2025

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Shunt-mediated decompression sickness in a compressed air worker with an atrial septal defect
Andrew P Colvin1,2, Ryan Hogg3, Peter T Wilmshurst4
1Tunnelmed Services Ltd, Dunblane, United Kingdom.
None:
We report a compressed air worker who had diffuse cutaneous decompression sickness with pain in his left shoulder and visual disturbance characteristic of migraine aura after only his third hyperbaric exposure. The maximum pressure was 253 kPa gauge with oxygen decompression using the Swanscombe Oxygen Decompression Table. He was found to have a very large right-to-left shunt across a 9 mm atrial septal defect. He had transcatheter closure of the defect but had some residual shunting with release of a Valsalva manoeuvre. Thirty-two other tunnel workers undertook the same pressure profile and activities in the same working conditions during the maintenance of a tunnel boring machine for a total of 233 similar exposures and were unaffected. As far as we are aware this is the first report of shunt-mediated decompression sickness in a hyperbaric tunnel worker in the United Kingdom and the second case reported worldwide. These cases suggest that shunt-mediated decompression sickness should be considered to be an occupational risk in modern compressed air working. A right-to-left shunt in a compressed air worker should be managed in accordance with established clinical guidance for divers.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Acute Respiratory Failure-III
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: