Related Experiment Video For PET/CT
Updated: May 5, 2026

Hybrid µCT-FMT imaging and image analysis
Published on: June 4, 2015
Interreader and Intrareader Reproducibility of 18F-Flotufolastat Image Interpretation in Patients with Newly
Phillip H Kuo1, Giuseppe Esposito2, Gary A Ulaner3,4
1Departments of Medical Imaging, Medicine, and Biomedical Engineering, University of Arizona, Tucson, Arizona; kuoradiology@gmail.com.
Abstract:
Interreader and intrareader reproducibility of 18F-flotufolastat PET/CT scans in newly diagnosed and recurrent prostate cancer patients was assessed from masked image evaluations from two phase 3 studies. Methods: 18F-flotufolastat PET/CT images of newly diagnosed (n = 352) or recurrent (n = 389) patients were evaluated by 3 masked readers. Cohen κ was used to assess pairwise patient- and region-level interreader agreement. Agreement among all readers was assessed using Fleiss κ. Intrareader agreement between the first and repeat read (20% of images, ≥4 wk later) was assessed using Cohen κ. Results: Pairwise interreader agreement was 95% or better (newly diagnosed) and 75% or better (recurrent). The κ coefficients were impacted by the high-agreement-low-κ paradox: Cohen κ ranged from not estimable to 0.55, whereas Fleiss κ was 0.50 (newly diagnosed) and 0.41 (recurrent). Agreement was highest in the prostate of newly diagnosed patients (≥95%) and in the pelvic lymph nodes in recurrent patients (≥87%). Intrareader agreement was 86% or better across both populations. Conclusion: 18F-flotufolastat PET/CT images can be reliably interpreted, with a high degree of inter- and intrareader agreement.