Related Experiment Video
Updated: Jun 3, 2026

Optimized System for Cerebral Perfusion Monitoring in the Rat Stroke Model of Intraluminal Middle Cerebral Artery Occlusion
Published on: February 17, 2013
Systematic Review and Meta-Analysis of Prehospital Machine Learning Scores as Screening Tools for Early Detection of
Muath Alobaida1,2,3, Martha Joddrell1,2, Yalin Zheng1,4
1Liverpool Centre for Cardiovascular Science University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital Liverpool UK.
Background:
Enhanced detection of large vessel occlusion (LVO) through machine learning (ML) for acute ischemic stroke appears promising. This systematic review explored the capabilities of ML models compared with prehospital stroke scales for LVO prediction.
Methods And Results:
Six bibliographic databases were searched from inception until October 10, 2023. Meta-analyses pooled the model performance using area under the curve (AUC), sensitivity, specificity, and summary receiver operating characteristic curve. Of 1544 studies screened, 8 retrospective studies were eligible, including 32 prehospital stroke scales and 21 ML models. Of the 9 prehospital scales meta-analyzed, the Rapid Arterial Occlusion Evaluation had the highest pooled AUC (0.82 [95% CI, 0.79-0.84]). Support Vector Machine achieved the highest AUC of 9 ML models included (pooled AUC, 0.89 [95% CI, 0.88-0.89]). Six prehospital stroke scales and 10 ML models were eligible for summary receiver operating characteristic analysis. Pooled sensitivity and specificity for any prehospital stroke scale were 0.72 (95% CI, 0.68-0.75) and 0.77 (95% CI, 0.72-0.81), respectively; summary receiver operating characteristic curve AUC was 0.80 (95% CI, 0.76-0.83). Pooled sensitivity for any ML model for LVO was 0.73 (95% CI, 0.64-0.79), specificity was 0.85 (95% CI, 0.80-0.89), and summary receiver operating characteristic curve AUC was 0.87 (95% CI, 0.83-0.89).
Conclusions:
Both prehospital stroke scales and ML models demonstrated varying accuracies in predicting LVO. Despite ML potential for improved LVO detection in the prehospital setting, application remains limited by the absence of prospective external validation, limited sample sizes, and lack of real-world performance data in a prehospital setting.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation