Purpose:
Customised individually made (CIM) total knee arthroplasty (TKA) with personalised alignment is relatively new and evidence is limited. The aim of this study was to compare patient-reported outcome measures between CIM and off-the-shelf (OTS) TKA patients in a matched-pair analysis with a 2-year follow-up.
Methods:
In this single-centre, prospective cohort study, propensity score matching was performed on 51 CIM and 51 OTS TKA. Data were measured at baseline, at 4 months, 1 and 2 years and included the Forgotten Joint Score (FJS-12), the High Activity Arthroplasty Score (HAAS), the Knee injury and Osteoarthritis Outcome Score (KOOS), the EQ-5D-3L, the EQ-Visual Analogue Scale, satisfaction, overall knee improvement, willingness to undergo the surgery again and the Knee Society Score.
Results:
At 2 years follow-up, the FJS-12 (77 vs. 67, p = .058), HAAS (13 vs. 11, p < .001), KOOS daily living (92 vs. 86, p = .029), KOOS sport (76 vs. 65, p = .019), KOOS quality of life (81 vs. 71, p = .028) and the EQ-5D (.95 vs. .90, p = .030) were higher for CIM TKA compared to OTS TKA. Satisfaction rate was 92% for CIM TKA and 84% for OTS TKA (p = .357). Most patients reported an improvement in the overall knee state (94% CIM and 90% OTS, p = .487) and almost all patients would undergo the surgery again (96% CIM and 98% OTS, p = .999).
Conclusion:
The current study found that CIM TKA patients had better functional outcomes at 2 years. Patient satisfaction was high and not statistically significantly different from OTS TKA patients.
Level Of Evidence:
Level II, prospective cohort study.