Related Experiment Video
Updated: Jun 23, 2025

Tissue-simulating Phantoms for Assessing Potential Near-infrared Fluorescence Imaging Applications in Breast Cancer Surgery
Published on: September 19, 2014
Evaluating silicone breast implant rupture with photon-counting CT and volumetric silicone maps
Todd C Soesbe1, Richard W Ahn1, Liqiang Ren1
1Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines BLVD, Dallas, TX 75390-9316, USA.
Abstract:
We present a case of an 81-year-old woman who presented to the emergency department with bleeding from a right breast wound. The patient had prior imaging suggestive of bilateral silicone implant rupture and a history of low tolerance for MRI scans. Ultrasound imaging in the emergency setting showed findings in the right breast suggestive of a fistula with free silicone and hematoma. A subsequent photon-counting CT scan with custom silicone-specific segmentation allowed differentiation of silicone from hematoma, provided anatomic assessment and location of the fistula, and revealed bilateral silicone-induced lymphadenopathy.