Related Experiment Video
Updated: Jun 23, 2025

Author Spotlight: Enhancing Rheumatoid Arthritis Research Through HR-pQCT Imaging Analysis
Published on: October 6, 2023
Deep learning-based classification of erosion, synovitis and osteitis in hand MRI of patients with inflammatory
Maja Schlereth1, Melek Yalcin Mutlu2,3, Jonas Utz4
1Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany maja.schlereth@fau.de.
Objectives:
To train, test and validate the performance of a convolutional neural network (CNN)-based approach for the automated assessment of bone erosions, osteitis and synovitis in hand MRI of patients with inflammatory arthritis.
Methods:
Hand MRIs (coronal T1-weighted, T2-weighted fat-suppressed, T1-weighted fat-suppressed contrast-enhanced) of rheumatoid arthritis (RA) and psoriatic arthritis (PsA) patients from the rheumatology department of the Erlangen University Hospital were assessed by two expert rheumatologists using the Outcome Measures in Rheumatology-validated RA MRI Scoring System and PsA MRI Scoring System scores and were used to train, validate and test CNNs to automatically score erosions, osteitis and synovitis. Scoring performance was compared with human annotations in terms of macro-area under the receiver operating characteristic curve (AUC) and balanced accuracy using fivefold cross-validation. Validation was performed on an independent dataset of MRIs from a second patient cohort.
Results:
In total, 211 MRIs from 112 patients (14 906 region of interests (ROIs)) were included for training/internal validation using cross-validation and 220 MRIs from 75 patients (11 040 ROIs) for external validation of the networks. The networks achieved high mean (SD) macro-AUC of 92%±1% for erosions, 91%±2% for osteitis and 85%±2% for synovitis. Compared with human annotation, CNNs achieved a high mean Spearman correlation for erosions (90±2%), osteitis (78±8%) and synovitis (69±7%), which remained consistent in the validation dataset.
Conclusions:
We developed a CNN-based automated scoring system that allowed a rapid grading of erosions, osteitis and synovitis with good diagnostic accuracy and using less MRI sequences compared with conventional scoring. This CNN-based approach may help develop standardised cost-efficient and time-efficient assessments of hand MRIs for patients with arthritis.
More Related Videos
12:23Flow Cytometry Analysis of Immune Cell Subsets within the Murine Spleen, Bone Marrow, Lymph Nodes and Synovial Tissue in an Osteoarthritis Model
Published on: April 24, 2020
07:15In vivo Macrophage Imaging Using MR Targeted Contrast Agent for Longitudinal Evaluation of Septic Arthritis
Published on: October 20, 2013
Related Concept Videos
Magnetic Resonance Imaging
Ultrasonography
During an ultrasonography procedure, a handheld device called...