The safety and efficacy of five surgical treatments in prostate enucleation: a network meta-analysis

Yun-Yi Chen1, Wen-Xi Hua2, Yu-Hua Huang1

  • 1Department of Urinary Surgery, The First Affiliated Hospital of Soochow University, Medical College of Soochow University, Suzhou, 215000, China.

BMC Urology
|June 17, 2024
PubMed
Abstract

Insights

This study compared five energy types for benign prostate hyperplasia surgery. Results showed no significant differences in complications, but Thulium:YAG and Thulium Fiber Laser offered better long-term outcomes.

Area of Science:

  • Urology
  • Minimally Invasive Surgery
  • Medical Technology Assessment

Background:

  • Benign prostate hyperplasia (BPH) affects a significant portion of the aging male population.
  • Various energy sources are utilized for endoscopic enucleation of the prostate (EEP) to treat BPH.
  • Comparative efficacy and recovery data for these energy sources are crucial for clinical decision-making.

Purpose of the Study:

  • To systematically review and compare the surgical efficacy and postoperative recovery of five distinct energy types used in BPH treatment.
  • To evaluate holmium laser enucleation of the prostate (HoLEP), Thulium:YAG laser enucleation of the prostate (ThuLEP), plasmakinetic enucleation of prostate (PKEP), diode laser enucleation of the prostate (DiLEP), and thulium fiber laser enucleation of the prostate (ThuFLEP).

Main Methods:

  • A systematic literature review was conducted across major databases (PubMed, Embase, Web of Science, Cochrane Library) up to December 1st, 2023.
  • Included clinical studies assessed HoLEP, ThuLEP, PKEP, DiLEP, and ThuFLEP for BPH treatment.
  • Network meta-analysis (NMA) was used to indirectly compare outcomes, with study quality assessed using Cochrane Risk of Bias and Newcastle-Ottawa Scale.

Main Results:

  • Thirty-eight studies (17 RCTs, 21 nRCTs) were analyzed, comparing five energy sources.
  • ThuLEP and HoLEP demonstrated shorter hospital stays and enucleation times compared to PKEP and ThuFLEP, respectively.
  • Thulium Fiber Laser and Holmium Laser yielded greater tissue weight than bipolar plasma; Thulium:YAG showed superior IPSS at 3 months, while Thulium Fiber Laser excelled in QoL and PVR at 12 months, with no significant complication differences across techniques.

Conclusions:

  • Despite theoretical differences, no significant clinical variations in operative parameters or complications were observed among the evaluated energy sources for BPH treatment.
  • The choice of laser energy source does not appear to significantly impact surgical outcomes.
  • Future research with larger sample sizes and multicenter designs is recommended to further validate these findings.