Related Experiment Video
Updated: Jun 23, 2025

Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
Published on: March 17, 2023
Highly Sensitive Flexible Capacitive Pressure Sensor Based on a Multicross-Linked Dual-Network Ionic Hydrogel for
Caixia Liu1, Fei Ma2, Qichang Sun1
1College of Physics, Hefei University of Technology, Hefei 230009, China.
Abstract:
Flexible capacitive pressure sensors based on ionic hydrogels (IHs) have garnered significant attention in the field of wearable technology. However, the vulnerability of traditional single-network hydrogels to mechanical damage and the complexity associated with preparing double-network hydrogels present challenges in developing a highly sensitive, easily prepared, and durable IH-based flexible capacitive pressure sensor. This study introduces a novel multicross-linked dual-network IH achieved through the physical and chemical cross-linking of polymers polyvinyl alcohol (PVA) and chitosan (CS), ionic solution H3PO4, and cross-linking agent gum arabic. Flexible capacitive pressure sensors, characterized by high sensitivity and a broad pressure range, are fabricated by employing mesh as templates to design cut-corner cube microstructures with high uniformity and controllability on the IHs. The sensor exhibits high sensitivity across a wide pressure range (0-290 kPa) and with excellent features such as high resolution (∼1.3 Pa), fast response-recovery time (∼11 ms), and repeatable compression stability at 25 kPa (>2000 cycles). The IHs as a dielectric layer demonstrate long-term water retention properties, enabling exposure to air for up to 100 days. Additionally, the developed sensor shows the ability to accurately measure the pulse wave within the small pressure range. By combining the pulse wave acquired by the sensor with a trained neural network model, we achieve successful blood pressure (BP) prediction, meeting the standards set by the Association for the Advancement of Medical Instrumentation and the British Hypertension Society. Ultimately, the sensor proposed in this study holds promising prospects for broad applications in high-precision wearable medical electronic devices.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement