A salivary urea sensor based on a microsieve disposable gate AlGaN/GaN high electron mobility transistor
Guo Yang1,2, Boxuan Xu2,3, Hui Chang2,4
1School of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun, Jilin, 130022, People's Republic of China.
Analytical Methods : Advancing Methods and Applications
|June 19, 2024
Summary
A novel biosensor using a micro-sieve and high electron mobility transistor (HEMT) effectively detects urea in saliva. This non-invasive device overcomes impurity interference, enhancing accuracy for real-time saliva testing applications.
Area of Science:
- * Biomedical Engineering
- * Materials Science
- * Analytical Chemistry
Background:
- * Saliva contains abundant biomarkers for non-invasive testing.
- * Saliva impurities often necessitate pre-processing, limiting convenient daily use of biosensors.
- * Existing high electron mobility transistor (HEMT) biosensors face signal interference from saliva's charged impurities.
Purpose of the Study:
- * To develop a HEMT biosensor integrated with a micro-sieve for improved saliva analysis.
- * To address signal interference caused by impurities in saliva for HEMT-based biosensors.
- * To enable accurate, real-time detection of specific markers in saliva.
Main Methods:
- * Fabricated a disposable-gate AlGaN/GaN HEMT biosensor.
- * Integrated a micro-sieve as a pre-treatment unit to remove large particles from saliva.
- * Evaluated sensor performance using urea detection in phosphate-buffered saline (PBS) and artificial/human saliva.
Main Results:
- * The HEMT biosensor demonstrated excellent linearity (R² = 0.9977) and high sensitivity (6.552 μA dec⁻¹) for urea sensing across a wide concentration range (1 fM to 100 mM).
- * The micro-sieve integration maintained high sensitivity in artificial saliva compared to sensors without the sieve.
- * Successful direct detection of urea in human saliva was achieved, validating the device's real-world applicability.
Conclusions:
- * The micro-sieve effectively removes impurities, enhancing the accuracy of HEMT biosensors for saliva analysis.
- * The integrated HEMT biosensor offers a promising platform for sensitive and real-time detection of biomarkers in saliva.
- * This technology has significant potential for rapid, non-invasive diagnostic applications using saliva.