Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Perspectives for capillary refill time in clinical practice for sepsis
Weipeng Huang1, Yiyan Huang2, Li Ke3
1Department of Critical Care Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou 310016, China; Department of Critical Care Medicine, Zhongnan Hospital of Wuhan University, Wuhan 430071, Hubei, China.
Capillary refill time (CRT) is a valuable tool for assessing sepsis, but requires standardized methods for reliable interpretation. Training physicians and minimizing environmental factors enhance its accuracy in clinical settings.
Area of Science:
- Critical care medicine
- Physiology
- Medical diagnostics
Background:
- Capillary refill time (CRT) measures peripheral circulation.
- CRT aids in guiding fluid therapy for sepsis.
- Inconsistent performance and interpretation limit CRT's clinical use.
Purpose of the Study:
- Provide physicians with a concise overview of CRT.
- Explore evidence on CRT's reliability and value in sepsis management.
Main Methods:
- Narrative review of existing literature.
Main Results:
- Identified factors influencing CRT: age, sex, temperature, light, technique, experience, training, and measurement differences.
- Synthesized methods to reduce CRT variability.
- Recommended a standardized CRT assessment method based on reproducible measurements and high inter-rater agreement.
- Discussed normal CRT thresholds and applications in sepsis management phases.
Conclusions:
- CRT is valuable in critically ill patients, particularly in sepsis.
- Standardized methods and trained personnel are crucial for accurate CRT assessment.
- CRT reflects microcirculation, perfusion, organ dysfunction, and outcomes, making it attractive for sepsis management.
- Further research is needed to confirm CRT's value in sepsis management.
More Related Videos
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Hand hygiene
Hand washing...