Related Experiment Video
Updated: Jun 23, 2025

Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies
Published on: April 11, 2016
Half-volume validation of the NGM Detect™ PCR Amplification Kit and its application on degraded casework samples
Nóra M Magonyi1, Bálint Megadja2, Katalin A Rádóczy1
1Department of Genetics, Hungarian Institute for Forensic Sciences, Budapest, Hungary.
The NGM Detect™ PCR Amplification Kit effectively genotypes degraded DNA samples using half-volume reactions. This kit provides valuable DNA profiles from challenging casework, even with low DNA input.
Area of Science:
- Forensic Science
- Molecular Biology
- Genetics
Background:
- Degraded DNA samples from casework present significant challenges in forensic analysis.
- Existing DNA amplification kits may struggle to generate complete profiles from low-quality DNA.
- The NGM Detect™ PCR Amplification Kit was developed to address these limitations.
Purpose of the Study:
- To validate the performance of the NGM Detect™ Kit using a half-volume polymerase chain reaction (PCR) system.
- To assess the kit's long-term application and effectiveness in genotyping degraded casework samples.
- To compare manual and robotic PCR preparation methods for DNA amplification.
Main Methods:
- Validation was conducted following guidelines from the Scientific Working Group on DNA analysis and the European Network of Forensic Science Institutes.
- Sensitivity, reproducibility, and repeatability were assessed using varying DNA input amounts (0.0375 ng to 0.5 ng).
- PCRs were performed with 29 cycles, increased to 31 for sub-optimal DNA input (≤0.5 ng).
- Eighty-four degraded casework samples were analyzed using manual PCR preparation.
Main Results:
- Optimal allelic peak heights and no allelic dropout were observed with 0.5 ng DNA input, irrespective of preparation method.
- Allelic dropout began to appear at 0.0375 ng DNA input, with manual PCRs showing fewer dropouts.
- Increased cycle numbers (31) resulted in 1.9% (manual) and 4.4% (robotic) dropout.
- Informative profiles were obtained for 78.57% (lowly), 70.37% (moderately), and 69.77% (highly) degraded samples.
- Allelic dropout rates were 26.05%, 44.88%, and 51.23% for lowly, moderately, and highly degraded samples, respectively.
Conclusions:
- The NGM Detect™ Kit is recommended for use in a half-volume PCR system for genotyping degraded DNA.
- The kit demonstrates successful long-term application and provides informative profiles from challenging forensic samples.
- Its usage is encouraged in cases where other kits fail to yield complete DNA profiles, particularly for degraded samples.
More Related Videos
08:08qPCR Is a Sensitive and Rapid Method for Detection of Cytomegaloviral DNA in Formalin-fixed, Paraffin-embedded Biopsy Tissue
Published on: July 9, 2014
11:49Enhanced Genetic Analysis of Single Human Bioparticles Recovered by Simplified Micromanipulation from Forensic ‘Touch DNA’ Evidence
Published on: March 9, 2015