Related Experiment Video
Updated: Jun 23, 2025

Author Spotlight: Context Dependent Blood Collection Methods in Rats
Published on: June 30, 2023
A comparative study of blood viscometers of 3 different types
Ju Seok Oh1, Prem Prabhakaran1, Dong Kil Seo2
1Department of Advanced Materials, Hannam University, Yuseonggu, Daejeon, Korea.
Abstract:
The greater the viscosity of the blood, the more difficult its flow becomes, leading to an increased incidence of diseases caused by blood circulation disorders. These diseases are commonly associated with the cardiovascular and cerebrovascular systems. High blood viscosity is a primary cause of circulatory system diseases. Studies have shown that accurately measuring blood viscosity and applying this data in clinical trials can help prevent circulatory system diseases. Viscosity data can vary depending on the measurement methods used, even when these methods are based on hydrodynamic principles. Despite using approved blood viscometers, the results often differ depending on the type of viscometer used, potentially causing confusion within the medical field. Informing the medical community about these differences and the level of error associated with each measurement method can help reduce this confusion. To our knowledge, the degree of difference in viscosity measurement results due to different measurement methods and the reasons for these differences have not yet been thoroughly explored. In this study, we selected three blood viscosity measurement methods registered with the Ministry of Food and Drug Safety of Korea to analyze the same canine blood. The viscosity measurements were carried out using each device and compared. The parallel plate and scanning capillary methods yielded similar viscosity values, while the cone plate method showed lower viscosity values. The viscosity of blood, as measured by the three viscometers, differed, indicating that more experimental data must be accumulated to evaluate the cause of these differences. In this paper, we identified several causes of inconsistency and suggested measures to avoid this confusion. However, confirming that the test results show systematic differences is expected to assist clinicians who diagnose and prescribe treatments based on blood viscosity results. The findings of this comparative study are anticipated to serve as a starting point for establishing guidelines or standards for blood viscosity measurement methods.
More Related Videos
08:03Quantitative Analysis of Viscoelastic Properties of Red Blood Cells Using Optical Tweezers and Defocusing Microscopy
Published on: March 25, 2022
07:42Modified Blood Collection from Tail Veins of Non-anesthetized Mice with a Vacuum Blood Collection System and Eyeglass Magnifier
Published on: February 2, 2019
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement