A comparative study of blood viscometers of 3 different types

Ju Seok Oh1, Prem Prabhakaran1, Dong Kil Seo2

  • 1Department of Advanced Materials, Hannam University, Yuseonggu, Daejeon, Korea.

The greater the viscosity of the blood, the more difficult its flow becomes, leading to an increased incidence of diseases caused by blood circulation disorders. These diseases are commonly associated with the cardiovascular and cerebrovascular systems. High blood viscosity is a primary cause of circulatory system diseases. Studies have shown that accurately measuring blood viscosity and applying this data in clinical trials can help prevent circulatory system diseases. Viscosity data can vary depending on the measurement methods used, even when these methods are based on hydrodynamic principles. Despite using approved blood viscometers, the results often differ depending on the type of viscometer used, potentially causing confusion within the medical field. Informing the medical community about these differences and the level of error associated with each measurement method can help reduce this confusion. To our knowledge, the degree of difference in viscosity measurement results due to different measurement methods and the reasons for these differences have not yet been thoroughly explored. In this study, we selected three blood viscosity measurement methods registered with the Ministry of Food and Drug Safety of Korea to analyze the same canine blood. The viscosity measurements were carried out using each device and compared. The parallel plate and scanning capillary methods yielded similar viscosity values, while the cone plate method showed lower viscosity values. The viscosity of blood, as measured by the three viscometers, differed, indicating that more experimental data must be accumulated to evaluate the cause of these differences. In this paper, we identified several causes of inconsistency and suggested measures to avoid this confusion. However, confirming that the test results show systematic differences is expected to assist clinicians who diagnose and prescribe treatments based on blood viscosity results. The findings of this comparative study are anticipated to serve as a starting point for establishing guidelines or standards for blood viscosity measurement methods.

Related Concept Videos

Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
957
Special considerations while measuring blood pressure01:28

Special considerations while measuring blood pressure

When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
717
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
580
Blood Studies I: ABG and VBG01:26

Blood Studies I: ABG and VBG

Blood studies are critical in the medical field, enabling healthcare professionals to assess a patient's health status accurately. This page will focus on two significant blood studies: Arterial Blood Gas (ABG) and Venous Blood Gas (VBG).
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
485
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
689