Related Experiment Video
Updated: Jun 23, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Carbon Dioxide Targets in Extracorporeal Membrane Oxygenation for Acute Respiratory Distress Syndrome
Torben M Rixecker1, Vanessa Ast1, Elianna Rodriguez2
1From the Department of Internal Medicine V (Pneumology, Allergology and Intensive Care Medicine), University Medical Center and Saarland University, Germany.
Abstract:
Target values for arterial carbon dioxide tension (PaCO 2 ) in extracorporeal membrane oxygenation (ECMO) for acute respiratory distress syndrome (ARDS) are unknown. We hypothesized that lower PaCO 2 values on ECMO would be associated with lighter sedation. We used data from two independent patient cohorts with ARDS spending 1,177 days (discovery cohort, 69 patients) and 516 days (validation cohort, 70 patients) on ECMO and evaluated the associations between daily PaCO 2 , pH, and bicarbonate (HCO 3 ) with sedation. Median PaCO 2 was 41 (interquartile range [IQR] = 37-46) mm Hg and 41 (IQR = 37-45) mm Hg in the discovery and the validation cohort, respectively. Lower PaCO 2 and higher pH but not bicarbonate (HCO 3 ) served as significant predictors for reaching a Richmond Agitation Sedation Scale (RASS) target range of -2 to +1 (lightly sedated to restless). After multivariable adjustment for mortality, tracheostomy, prone positioning, vasoactive inotropic score, Simplified Acute Physiology Score (SAPS) II or Sequential Organ Failure Assessment (SOFA) Score and day on ECMO, only PaCO 2 remained significantly associated with the RASS target range (adjusted odds ratio 1.1 [95% confidence interval (CI) = 1.01-1.21], p = 0.032 and 1.29 [95% CI = 1.1-1.51], p = 0.001 per mm Hg decrease in PaCO 2 for the discovery and the validation cohort, respectively). A PaCO 2 ≤40 mm Hg, as determined by the concordance probability method, was associated with a significantly increased probability of a sedation level within the RASS target range in both patient cohorts (adjusted odds ratio = 2.92 [95% CI = 1.17-7.24], p = 0.021 and 6.82 [95% CI = 1.50-31.0], p = 0.013 for the discovery and the validation cohort, respectively).
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-IV
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...