Background And Objective:
To evaluate the feasibility and accuracy of radiomics, dosiomics, and deep learning (DL) in predicting Radiation Pneumonitis (RP) in lung cancer patients underwent volumetric modulated arc therapy (VMAT) to improve radiotherapy safety and management.
Methods:
Total of 318 and 31 lung cancer patients underwent VMAT from First Affiliated Hospital of Wenzhou Medical University (WMU) and Quzhou Affiliated Hospital of WMU were enrolled for training and external validation, respectively. Models based on radiomics (R), dosiomics (D), and combined radiomics and dosiomics features (R+D) were constructed and validated using three machine learning (ML) methods. DL models trained with CT (DLR), dose distribution (DLD), and combined CT and dose distribution (DL(R+D)) images were constructed. DL features were then extracted from the fully connected layers of the best-performing DL model to combine with features of the ML model with the best performance to construct models of R+DLR, D+DLD, R+D+DL(R+D)) for RP prediction.
Results:
The R+D model achieved a best area under curve (AUC) of 0.84, 0.73, and 0.73 in the internal validation cohorts with Support Vector Machine (SVM), XGBoost, and Logistic Regression (LR), respectively. The DL(R+D) model achieved a best AUC of 0.89 and 0.86 using ResNet-34 in training and internal validation cohorts, respectively. The R+D+DL(R+D) model achieved a best performance in the external validation cohorts with an AUC, accuracy, sensitivity, and specificity of 0.81(0.62-0.99), 0.81, 0.84, and 0.67, respectively.
Conclusions:
The integration of radiomics, dosiomics, and DL features is feasible and accurate for the RP prediction to improve the management of lung cancer patients underwent VMAT.