Advancements in Ultrasound Techniques for Evaluating Intracranial Pressure Through Optic Nerve Sheath Diameter
Wei-Ze Fan1, Jun-Rong Jiang2, Hui-Ling Zang3
1Department of The Fifth Cardiology, The Second Hospital of Hebei Medical University, Shijiazhuang, China.
Abstract:
Elevated intracranial pressure (ICP) in patients with cerebral lesions has garnered considerable attention in research. It often manifests as a common symptom in conditions such as intracranial tumors, intracerebral hemorrhage, and cerebral edema. This paper provides an overview of ICP concepts, discusses the advantages and disadvantages of traditional monitoring methods, explores the physiological and anatomical aspects of the optic nerve sheath, examines the utility of ultrasound measurement of optic nerve sheath diameter (ONSD) in both nervous system and nonnervous system disorders, and outlines the cutoff values and normal ranges for assessing elevated ICP using ultrasound measurement of ONSD. The review underscores ultrasound measurement of ONSD as a promising noninvasive, safe, straightforward, and repeatable examination technique for various diseases. Nevertheless, the lack of standardized cutoff values for elevated ICP remains a challenge. Summarizing studies on optic nerve sheaths is crucial for enhancing the efficacy of ultrasound measurement of ONSD in assessing ICP.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure