The Presence of Implantable Cardioverter Defibrillators is Rarely Addressed During Code Status Change
Namratha Seetharam Meda1, Watipa Makhumalo2, Hunter Groninger3,4
1Department of Internal Medicine, MedStar Washington Hospital Center, Washington, DC, USA.
Abstract:
Background: Implantable Cardioverter Defibrillators (ICDs) are used to prevent sudden cardiac death, but they may provide unwanted shocks during end-of-life care. We aimed to study the frequency at which Do Not Resuscitate (DNR) discussions address ICD preferences in high-risk patients. Methods: A retrospective chart review was performed on patient hospitalizations with the presence of an ICD, a change in code status to DNR, and a subsequent death during that hospitalization. Data collected included demographics, significant comorbidities, if and when ICD was discussed, and who performed code status discussions, and were analyzed for statistical significance. Results: 129 patients met study criteria, and 110 patients (85.3%) did not have a documented discussion addressing ICD deactivation. There were no statistically significant differences in patient characteristics between patients with ICD addressed or not addressed, nor were there differences noted between discussions performed by residents vs staff or with the presence of cardiology, critical care status, or with palliative care consultation. It was noted that specifically discussing intubation or cardioversion was associated with the discussion of ICD deactivation. Conclusion: ICD discussions were rarely documented in our high-risk population, highlighting a potential need for better in-chart visibility of ICDs and for focused education of clinicians who care for these patients at end of life.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...