Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice
Published on: April 7, 2022
Myocardial performance imaging for the early identification of cardiac dysfunction in neonates with sepsis
Sudheshna Lalitha Sumbaraju1, Krishnananda Nayak2, Sridevi Prabhu3
1Department of Allied Health Sciences, Manipal Tata Medical College, Jamshedpur, Jharkhand, India.
Purpose:
The assessment of cardiac performance in septic new-borns is crucial for detecting hemodynamic instability and predicting outcome. The aim of the study is to assess myocardial performance in neonates with sepsis for the early identification of cardiac dysfunction.
Patients And Methods:
A case control study was carried out from September 2022 to May 2023 at the Neonatal Intensive care unit, Kasturba Medical College, Manipal. A total of 68 neonates were included in the study, with 33 females and 35 males. The study population was further subdivided into 3 groups namely preterm septic neonates (n = 21), term septic neonates (n = 10) and non-septic healthy controls (n = 37). The cardiac structure and function were assessed using conventional method, Tissue Doppler imaging (Sm) and speckle tracking echocardiography (GLS). The study was approved by the Institutional Ethics Committee at Kasturba Medical College, Manipal (approval number IEC: 90/2022). The CTRI registration number for the study is CTRI/2022/09/045437 and was approved on September 12, 2022. Prior to the neonate's enrolment, informed consent was obtained from their mothers or legal guardians.
Results:
Out of the total 68 neonates, 31 were cases and 37 were controls which included 33 females and 35 males. LV systolic function was not statistically significant between cases and controls. E/A ratio of the mitral valve was significantly lower in septic newborns than in healthy neonates. (1.01 ± 0.35 vs 1.18 ± 0.31, p < 0.05) preterm neonates showed significantly lower Lateral E' and RV E' velocities than term neonates. TAPSE was significantly lower in septic preterm neonates. (8.61 ± 1.28 vs. 10.7 ± 2.11, p < 0.05) No significant difference was noted in the Myocardial Performance Index between septic neonates and healthy neonates. LV Global Longitudinal Strain was slightly lower in preterm septic neonates than in term neonates with sepsis.
Conclusion:
Septic newborns are associated with LV diastolic dysfunction, RV systolic dysfunction and substantially higher pulmonary systolic pressures.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Dysrhythmias V: Evaluating Dysrhythmias