Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Enhancing gas chromatography-mass spectrometry resolution and pure analyte discovery using intra-chromatogram elution
Caitlin N Cain1, Robert E Synovec1
1Department of Chemistry, University of Washington, Box 351700, Seattle, WA, 98195, USA.
Abstract:
Chemometric decomposition methods like multivariate curve resolution-alternating least squares (MCR-ALS) are often employed in gas chromatography-mass spectrometry (GC-MS) to improve analyte identification and quantitation. However, these methods can perform poorly for analytes with a low chromatographic resolution (Rs) and a high degree of spectral contamination from noise and background interferences. Thus, we propose a novel computational algorithm, termed mzCompare, to improve analyte identification and quantitation when coupled to MCR-ALS. The mzCompare method utilizes an underlying requirement that the retention time and peak shape between mass channels (m/z) of the same analyte should be similar. By discovering the selective m/z for a given analyte in a chromatogram, a pure elution profile can be generated and used as an equality constraint in MCR-ALS. The performance of the mzCompare methodology is demonstrated with both experimental and simulated chromatograms. Experimentally, unresolved analytes with a Rs as low as 0.05 could be confidently identified with mzCompare assisted MCR-ALS. Furthermore, application of the mzCompare algorithm to a complex aerospace fuel resulted in the discovery of 335 analytes, a 44 % increase compared to conventional peak detection methods. GC-MS simulations of target-interferent analyte pairs demonstrated that the performance of MCR-ALS deteriorated below a Rs of ∼0.25. However, mzCompare assisted MCR-ALS showed excellent identification and acceptable quantitative accuracy at a Rs of ∼0.02. These results show that the mzCompare algorithm can help analysts overcome modeling ambiguities resulting from the chemometric multiplex disadvantage.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Elution Process
High-Resolution Mass Spectrometry (HRMS)