Assessment of radiation exposure risks in patients undergoing elastic stable intramedullary nailing: Insights from
A Safari1, F Falahati1, N Bahaedini2
1Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran; Department of Radiology, Paramedical School, Shiraz University of Medical Sciences, Shiraz, Iran.
Introduction:
Elastic stable intramedullary nailing (ESIN) is a well-defined and appropriate treatment of choice for long bone fractures. Despite its benefits, the risk of cancer from imaging devices is of particular concern for younger adults. So, this survey was conducted to estimate the doses administered to patients undergoing ESIN of long bone fractures utilizing a 2-dimensional (2D) C-arm fluoroscopy machine during surgery, as well as the carcinogenic risk associated with the use of the machine.
Methods:
This study was conducted on 147 patients who required ESIN for long-bone fractures. Patients' demographic data, surgical data and imaging information were collected. For each patient, the organ doses and the effective doses were computed with the Monte Carlo PCXMC 2.0 simulation software. The cancer risk models proposed in the Biological Effects of Ionizing Radiation VII (BEIR VII) Phase 2 report were used to evaluate the risk of exposure-induced cancer death (REID) values.
Results:
For all patients, the highest organ dose was delivered to the gonads. The mean effective dose was 0.026 ± 0.015 mSv and 1.3E-04 ± 1E-04 mSv for ESIN of femur and tibia fractures, respectively. Males had a mean REID of 1 per million, while females had a mean REID of 0.19 per million. The younger males had considerably higher REID values. The effective dose was significantly correlated with age, gender, and irradiation time.
Conclusion:
Low levels of effective doses and cancer risks associated with the utilization of the fluoroscopy machine in current practice were found in ESIN treatment of long-bone fractures.
Implications For Practice:
This outcome will help to raise surgeons' awareness of radiation risks and encourage them to initiate measures to keep radiation dose and exposure time as low as reasonably achievable.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...