Experimental and modeling study of medical waste based on plasma gasification
Hasan Amirahmadi1, Hamidreza FarshiFasih2, Shahrooz Saviz3
1Department of Mechanical Engineering, Faculty of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Abstract:
Plasma gasification melting (PGM) provides reliable disposal of toxic medical waste with a low heating value, which is capable of converting waste into energy. This study investigates the performance of experiments on plasma gasification for the treatment of chemical-pharmaceutical medical waste (CPMW) with an air medium. A comparative analysis is performed for gasification characteristics at three reactor temperatures (1000, 1400, and 1800 °C). Moreover, a thermodynamic equilibrium model is developed to assess performance features such as syngas yield, high heating value, and cold gas efficiency in the gasification temperature range of 1000-1800 °C. A comparison of the experiment and computational outcomes shows a good agreement. The results show that the quality of syngas and heating value is improved by increasing the temperature of the plasma gasifier so that at 1800 °C, H2, CO, and higher heating value (HHV) are obtained as 41 %, 37 %, and 10 MJ/Nm3, respectively. The obtained syngas is a clean fuel with low sulfur-containing and nitrogen-containing. The experimental results provide an extensive comprehension of CPMW gasification in a plasma reactor and consider a possibility for hydrogen and energy production.