Related Experiment Video
Updated: Jun 23, 2025

Reductive Electropolymerization of a Vinyl-containing Poly-pyridyl Complex on Glassy Carbon and Fluorine-doped Tin Oxide Electrodes
Published on: January 30, 2015
Evolution of the network structure and voltage loss of anode electrode with the polymeric dispersion in PEM water
Miaoyan Zhai1, Zihan Meng2, Rui Chen1
1State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, China.
Abstract:
Exploring the intrinsic relationship between the network structure and the performance of catalyst layer (CL) by rational design its structure is of paramount importance for proton exchange membrane (PEM) electrolyzers. This study reveals the relative effect of polymeric dispersion evolution on oxygen evolution reaction (OER) performance and cell voltage loss and linked to CL network structure. The results show that although the dispersed particle size of the ionomer and ink increases with increasing the solubility parameter (δ) difference between the mixed solvent and the ionomer, MeOH-cat (ink from MeOH aqueous solution) has the largest ionomer and ink particle size resulting in the poorest stability, but has comparable OER overpotential to that of IPA-cat (249 mV@10 mA cm-2), which has the smallest dispersed size. While at 100 mA cm-2, the overpotential of the ink rises as the particle size increases, suggesting that the electrode structure becomes more influential as the current density increases. Quantitatively analyzed the electrolyzers' voltage losses and determined that the CL from MeOH-cat has the lowest kinetic overpotential. However, its performance is the worst because of the insufficient network structure of CL, resulting in an output of 1.96 V at 1.5 A cm-2. Comparatively, the CL from IPA-cat has the highest kinetic overpotential yet can achieve the greatest performance of 1.76 V at 2 A cm-2 due to its homogeneous network structure and optimal mass transport. Furthermore, the performance variation becomes more pronounced as current density rises. Hence, this study highlights the significant impact of CL structure on electrolyzer's performance. To improve performance in PEM water electrolysis technology, especially for large work current density, it is crucial to enhance the CL's network structure.
More Related Videos
08:59Synthesizing a Gel Polymer Electrolyte for Supercapacitors, Assembling a Supercapacitor Using a Coin Cell, and Measuring Gel Electrolyte Performance
Published on: November 30, 2022
05:33Solid-state Graft Copolymer Electrolytes for Lithium Battery Applications