High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
Published on: June 21, 2011
Ultrahigh-Resolution K-Edge Imaging of Coronary Arteries With Prototype Deep-Silicon Photon-Counting CT: Initial
Thomas Wesley Holmes1, Zhye Yin1, Robert Bujila1
1From the Department of Radiology and Imaging Sciences (T.W.H., A.P.) and Winship Cancer Institute (A.P.), Emory University, 1701 Uppergate Dr, Ste 5018A, Atlanta, GA 30322; GE HealthCare, Waukesha, Wis (Z.Y., R.B., P.M., C.K., J.S.M.); and Department of Biomedical Engineering, Emory University-Georgia Institute of Technology, Atlanta, Ga (A.P.).
Abstract:
Background Photon-counting CT (PCCT) represents a recent advancement in CT, offering improved spatial resolution and spectral separability. By using multiple adjustable energy bins, PCCT enables K-edge imaging, allowing mixed contrast agent distinction. Deep-silicon is a new type of photon-counting detector with different characteristics compared with cadmium photon-counting detectors. Purpose To evaluate the performance of a prototype deep-Si PCCT scanner and compare it with that of a state-of-the-art dual-energy energy-integrating detector (EID) scanner in imaging coronary artery plaques enhanced with iodine and K-edge contrast agents. Materials and Methods A series of 10 three-dimensional-printed inserts (diameter, 3.5 mm) was prepared, and materials mimicking soft and calcified plaques were added to simulate stenosed coronary arteries. Inserts filled with an iodine- or gadolinium-based contrast agent (GBCA) were scanned. Virtual monoenergetic images (VMIs) and iodine maps were generated using two- and eight-energy bin data from EID CT and PCCT, respectively. Gadolinium maps were calculated for PCCT. The CT numbers of VMIs and iodine maps were compared. Spatial resolution and blooming artifacts were compared on the 70-keV VMIs in plaque-free and calcified coronary arteries. Results No evidence of a significant difference in the CT number of 70-keV images was found except in inserts containing GBCAs. In the absence of a GBCA, excellent (r > 0.99) agreement for iodine was found. PCCT could quantify the GBCA within 0.2 mg Gd/mL ± 0.8 accuracy of the ground truth, whereas EID CT failed to detect the GBCA. Lumen measurements were more accurate for PCCT than for EID CT, with mean errors of 167 versus 442 µm (P < .001) compared with the 3.5-mm ground truth. Conclusion Deep-Si PCCT demonstrated good accuracy in iodine quantification and could accurately decompose mixtures of two contrast agents. Its improved spatial resolution resulted in sharper images with blooming artifacts reduced by 50% compared with a state-of-the-art dual-energy EID CT scanner. © RSNA, 2024.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT