Ultrasensitive enantiomeric barbiturate analysis in body fluids through capillary electrophoresis with large volume sample stacking and ultrasound assisted dispersive liquid liquid microextraction
Related Experiment Video
Updated: Jun 23, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Meng-Chin Chen1, Ming-Mu Hsieh1, Xin-Yu Huang1
1Department of Chemistry, National Kaohsiung Normal University, Taiwan.
Abstract:
A rapid, straightforward, and sensitive approach to quantifying enantiomeric barbiturates in serum was developed by integrating ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) with large-volume sample stacking (LVSS) in capillary electrophoresis (CE). UA-DLLME was employed for sample preparation, and on-column preconcentration by using LVSS with polarity switching was implemented to enhance sensitivity. We thoroughly investigated and optimized various parameters influencing extraction and stacking to achieve optimal detection performance with the highest enrichment efficiencies. Under optimal extraction conditions (injection of a mixed solution containing 40 μL of CHCl3 and 200 μL of tetrahydrofuran into 1 mL of a sample solution at pH 10.0), LVSS was performed using 600 mM Tris-boric acid (pH 9.5) containing 35 mM hydroxypropyl-β-cyclodextrin and sodium taurodeoxycholate hydrate. A voltage of 20 kV was applied and a preinjection water plug was loaded at a height of 25 cm for 10 s. Subsequently, the sample solution was injected at a height of 25 cm for 480 s, after which a voltage of -20 kV was applied and the sample stacking was initiated. The stacking process was completed when 95 % of the separation current was attained. Under optimized conditions, the contraction folds of the four barbiturate analytes (R, S-Secobarbital, R, S-pentobarbital) were improved by approximately 6400-fold, achieving detection limits of 0.1 ng/mL. The limits of quantification for all analyte enantiomers were 0.5-50 ng/mL, demonstrating good linearity (r > 0.997). Migration times exhibited a relative standard deviation of less than 1.7 %, whereas peak areas for the four analytes exhibited a deviation of 8.7 %. Finally, the established method was effectively applied to the analysis of human serum samples.
More Related Videos
07:46Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors