Addressing the sources of inter-subject variability in E-field parameters in anodal tDCS stimulation over motor
Pablo Franco-Rosado1,2,3,4, M Amparo Callejón3,5, Javier Reina-Tosina3
1Unidad de Trastornos del Movimiento, Servicio de Neurología, Instituto de Biomedicina de Sevilla, Hospital Universitario Virgen del Rocío/CSIC/Universidad de Sevilla, Sevilla, Spain.
Abstract:
Objetive: .Although transcranial direct current stimulation constitutes a non-invasive neuromodulation technique with promising results in a great variety of applications, its clinical implementation is compromised by the high inter-subject variability reported. This study aims to analyze the inter-subject variability in electric fields (E-fields) over regions of the cortical motor network under two electrode montages: the classical C3Fp2 and an alternative P3F3, which confines more the E-field over this region.Approach.Computational models of the head of 98 healthy subjects were developed to simulate the E-field under both montages. E-field parameters such as magnitude, focality and orientation were calculated over three regions of interest (ROI): M1S1, supplementary motor area (SMA) and preSMA. The role of anatomical characteristics as a source of inter-subject variability on E-field parameters and individualized stimulation intensity were addressed using linear mixed-effect models.Main results.P3F3 showed a more confined E-field distribution over M1S1 than C3Fp2; the latter elicited higher E-fields over supplementary motor areas. Both montages showed high inter-subject variability, especially for the normal component over C3Fp2. Skin, bone and CSF ROI volumes showed a negative association with E-field magnitude irrespective of montage. Grey matter volume and montage were the main sources of variability for focality. The curvature of gyri was found to be significantly associated with the variability of normal E-fields.Significance.Computational modeling proves useful in the assessment of E-field variability. Our simulations predict significant differences in E-field magnitude and focality for C3Fp2 and P3F3. However, anatomical characteristics were also found to be significant sources of E-field variability irrespective of electrode montage. The normal E-field component better captured the individual variability and low rate of responder subjects observed in experimental studies.
More Related Videos
Related Concept Videos
Induced Electric Dipoles
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
Equipotential Surfaces and Conductors
Dielectric Polarization in a Capacitor
Induced Electric Fields
Induced Electric Fields: Applications
Electric Field of a Charged Disk
The system's symmetry is in the cylindrical directions across the plane of the charge. As a result, the electric fields created by various surface charge elements nullify each other in the direction parallel to the surface. Thereby, the resulting electric field is perpendicular to the plane. Since the disk is...