A retrospective study of deep learning generalization across two centers and multiple models of X-ray devices using
Pablo Menéndez Fernández-Miranda1,2, Enrique Marqués Fraguela3, Marta Álvarez de Linera-Alperi4
1Departamento de Radiología, Hospital Universitario Rey Juan Carlos, Calle Gladiolo, s/n, 28933, Móstoles, Spain.
Abstract:
Generalization of deep learning (DL) algorithms is critical for the secure implementation of computer-aided diagnosis systems in clinical practice. However, broad generalization remains to be a challenge in machine learning. This research aims to identify and study potential factors that can affect the internal validation and generalization of DL networks, namely the institution where the images come from, the image processing applied by the X-ray device, and the type of response function of the X-ray device. For these purposes, a pre-trained convolutional neural network (CNN) (VGG16) was trained three times for classifying COVID-19 and control chest radiographs with the same hyperparameters, but using different combinations of data acquired in two institutions by three different X-ray device manufacturers. Regarding internal validation, the addition of images from an external institution to the training set did not modify the algorithm's internal performance, however, the inclusion of images acquired by a device from a different manufacturer decreased the performance up to 8% (p < 0.05). In contrast, generalization across institutions and X-ray devices with the same type of response function was achieved. Nonetheless, generalization was not observed across devices with different types of response function. This factor was the key impediment to achieving broad generalization in our research, followed by the device's image-processing and the inter-institutional differences, which both reduced generalization performance to 18.9% (p < 0.05), and 9.8% (p < 0.05), respectively. Finally, clustering analysis with features extracted by the CNN was performed, revealing a substantial dependence of feature values extracted by the pre-trained CNN on the X-ray device which acquired the images.
More Related Videos
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
