Related Experiment Video
Updated: Jun 23, 2025

Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
FibroScan as a surveillance marker post-cavopulmonary anastomosis for single-ventricle physiology
Rupesh Kumar1, Mohamed Irshad Mohamed Refai1, Shyam Kumar Singh Thingnam1
1Department of Cardiothoracic and Vascular Surgery, Advanced Cardiac Centre, PGIMER, Room 4001, 4thFloor, Sector 12, Chandigarh, India.
Purpose:
Single-ventricle physiology encompasses a group of congenital cardiac malformations with only one functional ventricle. The Fontan procedure is the final palliation of this pathway and has its complications. One of these is Fontan-associated liver disease (FALD). It is known that all patients with Fontan will have FALD, due to the physiology of the Fontan circuit, and only the severity will vary. The pathophysiology of hepatic damage in FALD is unique and not easily detectable by routine non-invasive investigations. Therefore, this study is aimed to identify if FibroScan can be used as a surveillance marker to detect and assess the progression of FALD.
Methods:
Patients who attended the Cardiothoracic and Vascular Surgery Outpatient Department (OPD) for follow-up post-cavopulmonary anastomosis (bidirectional Glenn and Fontan) were enrolled in this study. They underwent routine examinations and tests, and in addition a FibroScan was performed.
Results:
FibroScan showed that the liver stiffness measurement (LSM) was increased in all patients who had undergone Fontan and a couple of patients who had undergone bidirectional (BD) Glenn. The LSM was 12.29 (± 3.59) kPa in patients post-Fontan and 6.64 (± 4.24) kPa in patients post-BD Glenn. This raised LSM was not associated with a parallel rise in liver enzymes or other laboratory markers associated with liver function. This emphasizes the suitability of FibroScan as an early and non-invasive surveillance tool for monitoring the progression of hepatic venous congestion and FALD.
Conclusion:
We have found that LSM via FibroScan can effectively be a surveillance or screening test for FALD. Serial FibroScans can be used to monitor the progress of liver disease. Raised LSM may also have a role in predicting the morbidity for completion of Fontan post-BD Glenn operation. Large-scale studies are needed to validate our findings.
More Related Videos
06:04Author Spotlight: Establishment and Confirmation of a Postnatal Right Ventricular Volume Overload Mouse Model
Published on: June 9, 2023
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...