A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
Published on: December 7, 2016
A Compact Differential Dynamic Microscopy-based Device (cDDM): An Approach Tool for Early Detection of
Touchwin Petiwathayakorn1, Narisara Paradee1, Sasinee Hantrakool2
1Department of Biochemistry, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand.
Abstract:
β-Thalassemia especially transfusion-dependent thalassemia (TDT) associates with a hypercoagulable state, which is the main cause of thromboembolic events (TEE). Plasma viscosity and rheological parameters could be essential markers for determining hypercoagulable state in β-thalassemia patients. The traditional methods for measuring viscosity are often limited by large sample volumes and are impractical for routine clinical monitoring. The compact differential dynamic microscopy-based device (cDDM), an optical microscopy for quantitative rheological assessment, was developed and applied for prognosis of the hypercoagulable state in β-TDT with and without splenectomy. The device was performed plasma viscosity measurement using low plasma volume (8 μL) and revealed a value as modulus of complex viscosity |η(ω)| in 7 min. We also parallelly demonstrated the correlation of the viscosity and related-coagulable parameters: complete blood count, prothrombin time (PT), activated partial thromboplastin time (APTT), protein C (PC), protein S (PS), CD62P and CD63 expression, and platelet aggregation test. The thalassemia plasma exhibited a higher value of |η(ω)| than healthy plasma, which can represent a different viscoelastic property among the groups. Even all related-coagulable parameters indicated hypercoagulable state in both nonsplenectomies and splenectomies β-TDT patients when compared to control, only high platelet numbers significantly correlated to high plasma viscosity in the splenectomy group. However, the other coagulable parameters have shown a trend of positive relationship with high plasma viscosity in all β-1thalassemia TDT patients. The relative results suggested that our device would be an approach tool for early detection of hypercoagulable state in transfusion-dependent-β-thalassemia patients, which can help to prevent TEE and the critical consequent-complications.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Therapeutic Drug Monitoring: Overview and Classification
Therapeutic Drug Monitoring: Drug Analysis Methods
Cardiomyopathy II: Dilated Cardiomyopathy